Xie Z et al., 2023-06-05: Retrospective single-centre study of 167 patients with 186 ultrasound BI-RADS 4A/4B lesions (145 category 4A, 41 category 4B), malignancy rate 34.9%. MRI reclassified lesions so that positive predictive value rose from 34.9% to 87.8% and 112 of 121 false-positive biopsies (92.6%) were avoided; sensitivity 100%, specificity 92.6%, NPV 100% (95% CI 96.8-100%). Four additional suspicious lesions were found only on MRI, three of them malignant.
MRI could downgrade suspicious lesions classified as BI-RADS 4A and 4B categories on US and avoided unnecessary benign biopsies without missing malignancy.
Abstract, Conclusions
Xie Z et al., 2023-06-05: Retrospective single-centre study of 167 patients with 186 ultrasound BI-RADS 4A/4B lesions (145 category 4A, 41 category 4B), malignancy rate 34.9%. MRI reclassified lesions so that positive predictive value rose from 34.9% to 87.8% and 112 of 121 false-positive biopsies (92.6%) were avoided; sensitivity 100%, specificity 92.6%, NPV 100% (95% CI 96.8-100%). Four additional suspicious lesions were found only on MRI, three of them malignant. Study type: retrospective single-centre diagnostic accuracy study. n=167 patients, 186 lesions. Country: China (authors' institution; single centre). Funding: PubMed lists 'Research Support, Non-U.S. Gov't'; the specific funder is not stated in the abstract retrieved. Declared conflicts: 'The authors declare no conflict of interest.' MRI: dynamic contrast-enhanced MRI plus diffusion-weighted imaging; field strength not stated in the abstract; BI-RADS assessment by two radiologists in consensus. Comparator: ultrasound BI-RADS category versus MRI BI-RADS category against histopathology and imaging follow-up of at least 12 months as reference standard. NUMBERS: NPV 100% (95% CI 96.8-100%) in this selected population with a 34.9% malignancy rate; the authors state MRI avoided unnecessary benign biopsies without missing malignancy. LABEL: single retrospective series supporting the use of MRI to downgrade equivocal breast lesions; design limits generalisability and a 100% NPV should not be read as a population guarantee. Retraction status: no retraction notice in the PubMed record. Study type: uncontrolled series.