Hogan JJ et al., 2016-02: Narrative review of native kidney biopsy indications, technique and complications from a US academic nephrology group. It tabulates major complication rates including nephrectomy 0.01% and death 0.02%, and reports higher transfusion rates with 14-gauge than with 16- or 18-gauge needles.
The use of 14-gauge needles has been associated with higher transfusion (2.1%) rates compared with 16- (0.4%) and 18-gauge (0.6%) needles (P=0.05)
Hogan JJ et al., 2016-02: Narrative review of native kidney biopsy indications, technique and complications from a US academic nephrology group. It tabulates major complication rates including nephrectomy 0.01% and death 0.02%, and reports higher transfusion rates with 14-gauge than with 16- or 18-gauge needles. States percutaneous ultrasound-guided biopsy with disposable automatic spring-loaded devices using 14-, 16- or 18-gauge needles is the current standard; the authors use 16-gauge automated needles in their own practice, which is at odds with the claim's 'usually 18-gauge'. Complication table (from Corapi 2012 pooled data) gives nephrectomy 0.01%, death 0.02%, transfusion 0.9%. No retraction or erratum notice in PubMed record (checked 2026-11-22). Study type: review.