NASA/Johnson Space Center et al., 1987-03: NASA's Space Station water quality conference report records chlorine dioxide or chlorite solution in developmental testing for the station shower and warns that chlorite accumulation could cause haemolytic anaemia and that chlorine dioxide interferes with thyroid function.
A bacteriostatic solution containing chlorine dioxide or chlorite was used during developmental testing
p. 4-30
NASA/Johnson Space Center et al., 1987-03: NASA's Space Station water quality conference report records chlorine dioxide or chlorite solution in developmental testing for the station shower and warns that chlorite accumulation could cause haemolytic anaemia and that chlorine dioxide interferes with thyroid function. C6 NASA water work, with the caution side recorded at full strength. Conference held 1-2 July 1986, report March 1987; panel chaired with external reviewers including Richard J. Bull. The report also lists chlorine dioxide among alternative disinfection processes to be considered alongside UV, halogenated resins, ozone and chlorine. Not a study: expert panel report, no subjects or doses. Direct PDF verified 200 application/pdf.