Ho ATN et al., 2023-02: Meta-analysis of four randomised trials (325 patients) comparing radial-EBUS transbronchial biopsy with CT-guided transthoracic biopsy for solitary lung nodules: higher yield with the CT route and five- to eight-fold less pneumothorax with the bronchoscopic route.
rEBUS-TBB had a significant better safety profile with lower risks of pneumothorax (2.87% vs 21.43%, OR = 0.12, 95% CI [0.05-0.32])
Ho ATN et al., 2023-02: Meta-analysis of four randomised trials (325 patients) comparing radial-EBUS transbronchial biopsy with CT-guided transthoracic biopsy for solitary lung nodules: higher yield with the CT route and five- to eight-fold less pneumothorax with the bronchoscopic route. Diagnostic yield 83.45% for CT-guided transthoracic biopsy versus 68.82% for radial-EBUS transbronchial biopsy (risk difference -0.15, 95% CI -0.24 to -0.05), and 83% versus 50% for lesions of 1-2 cm; pneumothorax 21.43% versus 2.87% (OR 0.12, 95% CI 0.05-0.32); composite of hospital admission, haemorrhage and pneumothorax 31.81% versus 8.62% (OR 0.21). Applies to radial EBUS without navigational technology. Retraction check: no retraction or erratum notice. Study type: review.