Severe Methemoglobinemia and Hemolytic Anemia from Aniline Purchased as 2C-E, a Recreational Drug, on the Internet – Oregon, 2011 (2012)

Peer-Reviewed Study · Centers for Disease Control and Prevention (MMWR) · February 10, 2012

Centers for Disease Control, 2012-02-10: CDC report of two men poisoned by aniline sold online as a recreational drug, both with severe methemoglobinemia refractory to methylene blue. It is the nearest documented U.S. case of an online-purchased chemical turning out to be aniline, but the year, product and circumstances differ from the incident described in the source.

DEA confiscated all product remaining in the men's possession, and FDA identified the substance as aniline, an industrial solvent known to cause methemoglobinemia.

Centers for Disease Control, 2012-02-10: CDC report of two men poisoned by aniline sold online as a recreational drug, both with severe methemoglobinemia refractory to methylene blue. It is the nearest documented U.S. case of an online-purchased chemical turning out to be aniline, but the year, product and circumstances differ from the incident described in the source. Study type: public health case report (two patients). N=2. Country: United States (Oregon). Dose in the report: methylene blue 1 mg/kg IV, repeated (5 doses in patient A; 4 in patient B); both patients' methemoglobinemia was refractory and required transfusion/plasmapheresis. Exposure: aniline, purchased over the internet from a Chinese chemical company, sold as 2C-E. Result: methaemoglobin peaked at 79.6% and 74.4%; one patient needed exchange transfusion. Note: recorded because it is the closest real primary document to the source's 'aniline contamination' incident. It is NOT about methylene blue as the contaminated product and is not from 2023 – the specific 2023 'industrial-grade methylene blue sold as supplement grade found to contain aniline' incident was not located in any primary document; see SOURCE NOT FOUND note in the flag report. HOST record is an HTML page (cdc.gov); no PDF was saved because the CDC PDF endpoint also returns 403 to automated clients, so pdf_url is blank. Also filed as MTF-59, MTF-54 (claims C11, C14, F2). Study type: case report.