Radiographic and clinical characterization of false negative results from CT-guided needle biopsies of lung nodules (2012)

Peer-Reviewed Study · Gelbman BD, Cham MD, Kim W, Libby DM, Smith JP, Port JL, Altorki NK, Henschke CI, Yankelevitz DF · May 2012

Gelbman BD et al., 2012-05: Consecutive series of 170 patients whose CT-guided transthoracic FNA of a lung nodule returned a benign result: 18 (10.6%) proved to be false negatives. False negatives had larger nodules, fewer imaging adjustments per pass, more often a needle tip not documented inside the lesion, and more pneumothorax than true negatives.

Computed tomography-guided transthoracic fine-needle aspiration (FNA) is a highly sensitive technique for diagnosing malignancy in pulmonary nodules; however, there is great uncertainty regarding the reliability of a benign result.

Abstract

Gelbman BD et al., 2012-05: Consecutive series of 170 patients whose CT-guided transthoracic FNA of a lung nodule returned a benign result: 18 (10.6%) proved to be false negatives. False negatives had larger nodules, fewer imaging adjustments per pass, more often a needle tip not documented inside the lesion, and more pneumothorax than true negatives. Retrospective consecutive case series (Jan 2002-Dec 2004); n=170 patients with an initial benign FNA result; United States (Weill Cornell Medical College, New York); funding not stated; declared conflicts not stated; device: CT-guided transthoracic fine-needle aspiration (needle gauge/make not stated); comparator: clinical and surgical follow-up establishing true versus false negative. Quoted from the PubMed abstract; full text paywalled. Retraction status: PubMed record type 'Journal Article'; no CommentsCorrections entry and no retraction or expression of concern in the record. Study type: uncontrolled series.