Phenothiazine Derivative-Accelerated Microbial Extracellular Electron Transfer in Bioelectrochemical System (2013)

Peer-Reviewed Study · Liu XW, et al. · 2013

Liu XW et al., 2013: Primary electrochemistry paper reporting a measured redox potential of 0.011 V for methylene blue at pH 7.0 versus the standard hydrogen electrode, among the lowest of the phenothiazine dyes tested.

MB had a lowest redox potential of 0.011 V, and also possessed the largest peak current density among the three phenothiazine derivatives.

Results (Figure 1 discussion)

Liu XW et al., 2013: Primary electrochemistry paper reporting a measured redox potential of 0.011 V for methylene blue at pH 7.0 versus the standard hydrogen electrode, among the lowest of the phenothiazine dyes tested. Primary experimental study (electrochemistry/microbiology), not a clinical study; no human subjects; no methylene blue dose given to patients. DOI 10.1038/srep01616; Sci Rep 2013;3:1616. The 0.011 V figure is the standard redox potential (E0') of the MB/leucomethylene blue couple at pH 7.0 vs SHE, the value repeated in the source's chemistry chapter. Study type: lab.