Rimondi E et al., 2010-09-15: Eighteen years of single-institution CT-guided core needle biopsy of musculoskeletal lesions (2,027 biopsies): the first biopsy gave the correct diagnosis in 77.3% of cases; 408 samples were non-diagnostic and 52 inadequate, and a repeat biopsy within 30 days raised final diagnostic accuracy to 94%. False negatives clustered in cervical lesions and in benign, pseudotumoral, inflammatory and systemic disease.

In 1567 cases the correct diagnosis was made with the first CT-guided needle biopsy (77.3% accuracy rate), in 408 cases the sample was not diagnostic and in 52 inadequate.

Abstract

Rimondi E et al., 2010-09-15: Eighteen years of single-institution CT-guided core needle biopsy of musculoskeletal lesions (2,027 biopsies): the first biopsy gave the correct diagnosis in 77.3% of cases; 408 samples were non-diagnostic and 52 inadequate, and a repeat biopsy within 30 days raised final diagnostic accuracy to 94%. False negatives clustered in cervical lesions and in benign, pseudotumoral, inflammatory and systemic disease. Retrospective single-institution cohort (about 18 years); n=2,027 core needle biopsies; Italy (Istituto Ortopedico Rizzoli, Bologna); funding not stated; declared conflicts not stated; device: CT-guided core needle (make/gauge not stated); comparator: subsequent open/surgical histology and repeat biopsy. Quoted from the PubMed abstract; full text paywalled. Retraction status: PubMed record type 'Journal Article'; no CommentsCorrections entry and no retraction or expression of concern in the record. Study type: uncontrolled series.