Non-infectious complications following transrectal prostate needle biopsy – Outcomes from over 8000 procedures (2022)

Peer-Reviewed Study · Sosenko A, Owens RG, Yang AL, et al. · April 23, 2022

Sosenko A et al., 2022-04-23: Retrospective review of 8,102 transrectal ultrasound-guided prostate needle biopsies in a Pennsylvania statewide quality registry (2015-2018). 277 (3.4%) had reported post-procedure complications, of which 199 (2.5%) were non-infectious and 78 (0.9%) infectious. Non-infectious events included urinary or rectal bleeding (74; 0.9%), urinary retention (70; 0.9%), vasovagal syncope (13; 0.2%) and severe post-operative pain (10; 0.1%); 56% (111/199) required an emergency department visit and 27% (54/199) hospital admission. Larger prostate volume was associated with urinary retention (OR 1.07, 1.02-1.11, p = 0.002).

Among the non-infectious complications, the most common events included urinary or rectal bleeding (74; 0.9%), urinary retention (70, 0.9%), vasovagal syncope (13, 0.2%), and severe post-operative pain (10, 0.1%).

Sosenko A et al., 2022-04-23: Retrospective review of 8,102 transrectal ultrasound-guided prostate needle biopsies in a Pennsylvania statewide quality registry (2015-2018). 277 (3.4%) had reported post-procedure complications, of which 199 (2.5%) were non-infectious and 78 (0.9%) infectious. Non-infectious events included urinary or rectal bleeding (74; 0.9%), urinary retention (70; 0.9%), vasovagal syncope (13; 0.2%) and severe post-operative pain (10; 0.1%); 56% (111/199) required an emergency department visit and 27% (54/199) hospital admission. Larger prostate volume was associated with urinary retention (OR 1.07, 1.02-1.11, p = 0.002). Retrospective registry analysis; 8,102 biopsies from more than 100 urologists across health systems; USA (Pennsylvania); funding: no grant support listed in the PubMed record; conflicts: 'The authors have no conflict of interest pertaining to the material published in this manuscript'; device: transrectal ultrasound-guided needle biopsy, needle make/model not named; comparator: none (descriptive incidence with logistic regression for predictors); retraction check: no retraction notice in the PubMed record (checked 2026-11-22); English.