Lee CH et al., 1999-07: Of 540 stereotactic core-needle biopsies, 355 were benign and 298 of those had follow-up mammography: 7% changed at 6-55 months, 21 showed mammographic change, 18 of these were re-biopsied and two proved malignant, which the authors express as a delayed false-negative rate of 2% (two of 105 malignancies among the 540 biopsies).
This represented a delayed false-negative rate of 2% (two of 105 malignancies among 540 biopsies).
Abstract
Lee CH et al., 1999-07: Of 540 stereotactic core-needle biopsies, 355 were benign and 298 of those had follow-up mammography: 7% changed at 6-55 months, 21 showed mammographic change, 18 of these were re-biopsied and two proved malignant, which the authors express as a delayed false-negative rate of 2% (two of 105 malignancies among the 540 biopsies). Retrospective cohort with mammographic follow-up (July 1992-December 1995); n=540 biopsies, 298 benign cases with follow-up; United States (Yale University School of Medicine, New Haven, CT); funding not stated; declared conflicts not stated; device: stereotactic core-needle biopsy (gauge/make not stated); comparator: follow-up mammography and repeat biopsy. Note this is a delayed false-negative rate measured through follow-up, not a surgical reference standard. Quoted from the PubMed abstract; full text paywalled. Retraction status: PubMed record type 'Journal Article'; CommentsCorrections lists only the 2000 Radiology letter (PMID 10924594), not a retraction; no retraction or expression of concern in the record. Study type: uncontrolled series.