Arentz J et al., 2021-12-02: German in vitro study of photodynamic inactivation: 0.001% methylene blue with LED or laser light reduced bovine coronavirus by 5.29 to 5.31 log and 0.0001% by 4.6 to 5.31 log, while methylene blue in the dark barely reduced virus (0.9 and 1.23) – a clean demonstration that this application depends on light.
In contrast approaches of BCoV-infected cells in the dark, treated with 0.001% and 0.0001% MB sensitizer alone, a lot of residual viruses could be detected after 10 minutes of incubation (RF 0.9 and RF 1.23 for 0.001% MB and 0.0001% MB respectively)
Abstract
Arentz J et al., 2021-12-02: German in vitro study of photodynamic inactivation: 0.001% methylene blue with LED or laser light reduced bovine coronavirus by 5.29 to 5.31 log and 0.0001% by 4.6 to 5.31 log, while methylene blue in the dark barely reduced virus (0.9 and 1.23) – a clean demonstration that this application depends on light. Study type: in vitro (BCoV in U373 cells; SARS-CoV-2 in Vero E6). Light sources: 810 nm diode laser 300 mW/cm2 at 100 J/cm2; 590 nm LED and broadband LED at 10,000 lx for 2.5, 5 and 10 min. MB 0.001% and 0.0001%. Country: Germany. Comparator: dark incubation with MB alone. Funding/COI not stated in the retrieved abstract record. Direct relevance: the best evidence in this claim that light is the active ingredient for the local (nasal) use case. Also filed as MTD-008, MTD-097 (claims C1, C3, F2). Study type: lab.