Seeff LB et al., 2010-10: Prospective complication analysis of 2,740 percutaneous liver biopsies in patients with hepatitis C and bridging fibrosis or cirrhosis, reporting 1.1% serious adverse events, 0.6% bleeding and no deaths, with bleeding related to platelet count and INR.
There were 29 serious adverse events (1.1%); the most common was bleeding (16 cases, 0.6%). There were no biopsy-related deaths.
Seeff LB et al., 2010-10: Prospective complication analysis of 2,740 percutaneous liver biopsies in patients with hepatitis C and bridging fibrosis or cirrhosis, reporting 1.1% serious adverse events, 0.6% bleeding and no deaths, with bleeding related to platelet count and INR. Serious adverse events 29 (1.1%), bleeding 16 (0.6%), no biopsy-related deaths. Bleeding was more frequent with platelets at or below 60,000/mm3 and INR at or above 1.3, 'although none of the patients with an INR >1.5 bled'; excluding platelets at or below 60,000/mm3 would have removed 25% of bleeds (4/16) while excluding 2.8% of biopsies. Needles as printed: 60% cutting, mostly 16 gauge, 40% aspiration; about 80% bedside ultrasound; all centres required full blood count, platelets and PT/INR; 40% required platelets of at least 70,000 and the rest allowed as low as 50,000. Operator experience, needle type and ultrasound guidance did not change adverse-event rates. Retraction check: no retraction or erratum notice.