Comparison of coaxial technique with sequential (non-coaxial) technique for renal mass biopsy: evaluation of diagnostic efficacy, complication rates, seeding risk, and clinical outcomes (2026)

Peer-Reviewed Study · Garcia MP, Finelli A, Bhayana R, Schieda N, Kachura J, Basso Dias A, Raveendran L, Abreu Gomez J, Jajodia A, Martin L, Prendeville S, Krishna S · February 2026

Garcia MP et al., 2026-02: Retrospective single-centre study of 1,174 small renal masses biopsied 2004-2020 (59% coaxial, 41% sequential): diagnostic yield, upstaging to pT3a and recurrence did not differ, tumour seeding was found in 2 patients (both papillary RCC, one per technique) and did not recur.

There were 2 subjects with tumor seeding (tiny fragments in the perinephric fat beside the renal mass in the resected surgical specimen), one patient with each technique.

Garcia MP et al., 2026-02: Retrospective single-centre study of 1,174 small renal masses biopsied 2004-2020 (59% coaxial, 41% sequential): diagnostic yield, upstaging to pT3a and recurrence did not differ, tumour seeding was found in 2 patients (both papillary RCC, one per technique) and did not recur. Item C1-22. Study type: retrospective comparative cohort (case-control per the authors' methodology statement). Number of subjects: 1,174 small renal masses. Country: Canada (University of Toronto). Funding: no funding statement in the PubMed record. Declared conflicts: 'The authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article.' Device: coaxial versus sequential (non-coaxial) biopsy needles; makes and gauges not named in the abstract. Comparator: biopsy technique, plus resected specimens after nephrectomy. Retraction check: no retraction notice in the PubMed record; the paper has a published 'Comment in' (Eur Radiol 2026;36:987-988), not a retraction. Bearing note: seeding occurred in 2 patients, confirming it as a documented event, while the study finds no protective effect of the coaxial technique. Excerpt from the PubMed abstract. Study type: controlled study.