NHS Breast Screening Programme / Public Health England, 2016-11: UK national guidance for assessment in breast screening. It requires core biopsy or vacuum-assisted biopsy for significant abnormalities, names ultrasound as the technique of choice for guided sampling, advises marker (clip) insertion, and uses the B1-B5 pathology categories.
Ultrasound is the technique of choice for guided needle sampling. A permanent record of images showing the biopsy needle in the target lesion should be made. VACB should be used for re-biopsy and in the investigation of B3 lesions.
13
NHS Breast Screening Programme / Public Health England, 2016-11: UK national guidance for assessment in breast screening. It requires core biopsy or vacuum-assisted biopsy for significant abnormalities, names ultrasound as the technique of choice for guided sampling, advises marker (clip) insertion, and uses the B1-B5 pathology categories. No study population; expert-group guidance informed by cited literature. Public body, no individual conflicts printed. No device make or model. States significant abnormalities 'should be assessed by core biopsy or vacuum-assisted core biopsy (VACB)', that cytology should no longer be used alone, that a permanent record of needle-in-lesion images be made, and that a marker (clip) is recommended with mammographic documentation of position. Uses B1-B5 reporting categories (B3 = 'of uncertain malignant potential'). The current gov.uk edition (updated 22 January 2026) restates the same pathway; this row quotes the dated 2016 PDF. Retraction check: none applicable.