Breast lesions with ultrasound imaging-histologic discordance at 16-gauge core needle biopsy: can re-biopsy with 10-gauge vacuum-assisted system get definitive diagnosis? (2010)

Peer-Reviewed Study · Li JL, Wang ZL, Su L, Liu XJ, Tang J · September 24, 2010

Li JL et al., 2010-09-24: In 1,069 breast lesions biopsied with ultrasound-guided 16-gauge core needle biopsy, 28 lesions were judged imaging-histologically discordant and all underwent re-biopsy with a 10-gauge vacuum-assisted biopsy system; six of the 28 (21.4%) were upgraded pathologically at re-biopsy, and all malignant lesions found at VAB were treated surgically while benign ones were followed at least one year.

Six of the 28 lesions (21.4%) had pathologic upgrade after VAB.

Abstract

Li JL et al., 2010-09-24: In 1,069 breast lesions biopsied with ultrasound-guided 16-gauge core needle biopsy, 28 lesions were judged imaging-histologically discordant and all underwent re-biopsy with a 10-gauge vacuum-assisted biopsy system; six of the 28 (21.4%) were upgraded pathologically at re-biopsy, and all malignant lesions found at VAB were treated surgically while benign ones were followed at least one year. Study type: prospective/clinical consecutive series (the PubMed PublicationType list includes Clinical Trial). n=1,069 lesions biopsied; 28 discordant lesions re-biopsied. Country: China (Department of Ultrasound, Chinese People's Liberation Army General Hospital, Beijing). Funding: not stated in the PubMed record. Declared conflicts of interest: not stated in the PubMed record. Device/needle: 16-gauge automated core needle biopsy for the index biopsy, 10-gauge vacuum-assisted biopsy (VAB) system for re-biopsy; manufacturer and model not stated in the abstract. Comparator: VAB re-biopsy result versus subsequent surgical pathology and at least 1 year of follow-up. CommentsCorrections: none listed; no retraction notice. Quoted text is from the PubMed abstract of the article. Peer review: journal peer review; reviewers not named in the published record. Study type: uncontrolled series.