Poloni JAT et al., 2018-03-31: Case report of a woman taking methenamine 120 mg plus methylthioninium chloride 20 mg whose urine was blue-green and gave a false nephrotic-range protein result on dipstick (3+) against 18 mg/dL by turbidimetry – documented methylene blue interference in urinalysis.
The albuminuria measured by dipstick shows 3+ (300 mg/dL), but in turbidimetric method the urine protein concentration was 18 mg/dL, showing an important interference of methylene blue on the dipstick albumin area.
Poloni JAT et al., 2018-03-31: Case report of a woman taking methenamine 120 mg plus methylthioninium chloride 20 mg whose urine was blue-green and gave a false nephrotic-range protein result on dipstick (3+) against 18 mg/dL by turbidimetry – documented methylene blue interference in urinalysis. C8. Study type: case report with laboratory confirmation. N: 1. Country: Brazil (University of Sao Paulo author group; Perazella co-author, USA). Product: methenamine 120 mg + methylthioninium chloride 20 mg, oral (a urinary combination product of the type named in the brief). Funder/conflicts: none declared in the record. Comparator: dipstick vs turbidimetric protein. Relevant to C8 as assay interference by the dye in a urological specimen, not to PSA. Study type: case report.