Minot DM et al., 2014-05-28: Blinded rereview of 36 false-negative CT-guided transthoracic FNA/core biopsy cases out of 1,043 consecutive patients: 11 (about 31%) were interpretive errors on rereview and 25 (69.4%) were sampling errors, giving an overall false-negative rate of 3.5% (1.1% interpretive, 2.4% sampling).
The remaining 25 FN cases (69.4%) were considered sampling errors and consisted of 7 adenocarcinomas, 3 nonsmall cell carcinomas, 3 lymphomas, 2 squamous cell carcinomas, and 2 renal cell carcinomas.
Abstract
Minot DM et al., 2014-05-28: Blinded rereview of 36 false-negative CT-guided transthoracic FNA/core biopsy cases out of 1,043 consecutive patients: 11 (about 31%) were interpretive errors on rereview and 25 (69.4%) were sampling errors, giving an overall false-negative rate of 3.5% (1.1% interpretive, 2.4% sampling). Retrospective cohort with blinded three-pathologist rereview; n=1,043 consecutive patients, 37 false-negative cases (36 reread); United States (Mayo Clinic, Rochester, Minnesota); funding not stated; declared conflicts not stated; test: CT-guided transthoracic FNA with or without core needle biopsy (needles not stated); comparator: subsequent malignant outcome/surgical pathology, with positive and negative matched controls. Directly separates sampling error from interpretive error. Quoted from the PubMed abstract; full text paywalled. Retraction status: PubMed record type 'Journal Article'; no CommentsCorrections entry and no retraction or expression of concern in the record.