2020 Clinical Practice Guideline for Percutaneous Transthoracic Needle Biopsy of Pulmonary Lesions: A Consensus Statement and Recommendations of the Korean Society of Thoracic Radiology (2020)

Peer-Reviewed Study · Yoon SH, Lee SM, Park CH, Lee JH, Kim H, Chae KJ, Jin KN, Lee KH, Kim JI, Hong JH, Hwang EJ, Kim H, Suh YJ, Park S, Park YS, Kim DW, Choi M, Park CM · November 19, 2020

Yoon SH et al., 2020-11-19: Consensus clinical practice guideline of the Korean Society of Thoracic Radiology. It summarises four national surveys and large cross-sectional analyses – United Kingdom (5,444 biopsies), Japan (9,783), Korea (10,568) and United States (15,865) – as reporting pneumothorax rates of 15.0-35.0% and pneumothorax requiring tube drainage in 3.1-6.6%. It lists higher pneumothorax risk with older age, male sex, smoking, emphysema (especially along the needle path), deep-seated lesions, smaller lesion size, subpleural lesions, more pleural passages, lateral pleural puncture and fissure traversal.

National multicenter surveys or large cross-sectional analyses in the United Kingdom (5444 biopsies), Japan (9783 biopsies), Korea (10568 biopsies), and United States (15865 biopsies) reported pneumothorax rates of 15.0-35.0% and rates of pneumothorax requiring tube drainage of 3.1-6.6%

Yoon SH et al., 2020-11-19: Consensus clinical practice guideline of the Korean Society of Thoracic Radiology. It summarises four national surveys and large cross-sectional analyses – United Kingdom (5,444 biopsies), Japan (9,783), Korea (10,568) and United States (15,865) – as reporting pneumothorax rates of 15.0-35.0% and pneumothorax requiring tube drainage in 3.1-6.6%. It lists higher pneumothorax risk with older age, male sex, smoking, emphysema (especially along the needle path), deep-seated lesions, smaller lesion size, subpleural lesions, more pleural passages, lateral pleural puncture and fissure traversal. Item: Korean Society of Thoracic Radiology 2020 consensus guideline. Study type: clinical practice guideline (consensus statement and recommendations). Country: Korea (multidisciplinary panel; evidence drawn from UK, Japanese, Korean and US national data). Funding: supported and funded by the Korean Society of Thoracic Radiology and the Korean Society of Radiology. Conflicts of interest: 'The authors have no potential conflicts of interest to disclose.' Device: guidance covers needle type, gauge and coaxial technique generally; no single make/model. Comparator: pooled national survey rates and published risk-factor literature. Retraction check: Europe PMC record for PMID 33236542 lists no retraction or comment.