Meta-analysis and systematic review of the diagnostic value of contrast-enhanced spectral mammography for the detection of breast cancer (2024)

Peer-Reviewed Study · Liu J, Xiao R, Yin H, Hu Y, Zhen S, Zhou S, Han D · September 3, 2024

Liu J et al., 2024-09-03: Systematic review of 12 studies of contrast-enhanced spectral mammography (CESM): pooled sensitivity 0.97, specificity 0.76, positive likelihood ratio 4.03, negative likelihood ratio 0.05, diagnostic odds ratio 89.49 and area under the curve 0.95, with the authors concluding CESM has high sensitivity and good specificity, particularly in dense breasts.

According to the summary estimates for CESM in the diagnosis of breast cancer, the pooled sensitivity and specificity were 0.97 (95% CI 0.92 to 0.98) and 0.76 (95% CI 0.64 to 0.85), respectively.

Results (abstract)

Liu J et al., 2024-09-03: Systematic review of 12 studies of contrast-enhanced spectral mammography (CESM): pooled sensitivity 0.97, specificity 0.76, positive likelihood ratio 4.03, negative likelihood ratio 0.05, diagnostic odds ratio 89.49 and area under the curve 0.95, with the authors concluding CESM has high sensitivity and good specificity, particularly in dense breasts. Study type: systematic review and meta-analysis of diagnostic accuracy. n=12 studies; number of patients not stated in the abstract. Country of authors: China; countries of the included studies not stated in the abstract. Funding: not stated in the retrieved record. Declared conflicts: 'Competing interests: None declared.' Imaging: contrast-enhanced spectral mammography (iodinated contrast, dual-energy acquisition), compared in the included studies against histopathology and/or other imaging. Comparator: histopathology reference standard and, in the source studies, conventional mammography, ultrasound and MRI. NUMBERS: a negative likelihood ratio of 0.05 implies a high negative predictive value at the prevalences studied, but the pooled abstract does not report an NPV, so no NPV figure is asserted here. LABEL: evidence that contrast-enhanced mammography can function as a sensitive imaging triage; it does not show that a negative study can replace biopsy in a specified population. Retraction status: no retraction notice; PubMed lists it as Systematic Review, Meta-Analysis. Study type: review.