Sakamoto N et al., 2009-05-12: Retrospective review of 986 consecutive ultrasound-guided 11-gauge vacuum-assisted breast biopsies (835 patients) found an overall false-negative rate of 7.4% (13/175 malignancies); the rate was 26% (8/31) in lesions seen only on MRI versus 3.5% (5/144) in lesions detected on ultrasound, a significant difference the authors attribute to difficulty correlating MRI findings with ultrasound.
The false-negative rate for MRI-detected lesions (26%; 8/31) was significantly higher than that for US-detected lesions (3.5%; 5/144) (P = 0.0002).
Abstract
Sakamoto N et al., 2009-05-12: Retrospective review of 986 consecutive ultrasound-guided 11-gauge vacuum-assisted breast biopsies (835 patients) found an overall false-negative rate of 7.4% (13/175 malignancies); the rate was 26% (8/31) in lesions seen only on MRI versus 3.5% (5/144) in lesions detected on ultrasound, a significant difference the authors attribute to difficulty correlating MRI findings with ultrasound. Retrospective cohort; n=986 lesions in 835 patients (175 malignant); Japan (Breast Center, Kameda Medical Center, Chiba); funding not stated; declared conflicts not stated; device: 11-gauge ultrasound-guided vacuum-assisted biopsy probe (make/model not stated); comparator: final surgical pathology and follow-up, with US-detected versus MRI-detected lesion subgroups. Quoted from the PubMed abstract; full text paywalled. Retraction status: PubMed record type 'Journal Article'; no CommentsCorrections entry and no retraction or expression of concern in the record.