Bone marrow biopsy morbidity and mortality: 2002 data. (2004)

Peer-Reviewed Study · Bain BJ · October 2004

Bain BJ, 2004-10: Survey for the British Society for Haematology covering 2002: 53 centres reported 13,506 procedures with 17 adverse events; the adverse event may have contributed to death in two patients and was life-threatening in a third.

There were 17 adverse events including nine instances of haemorrhage, four infections and one haemorrhage complicated by infection. Two trephine biopsy needles broke during the procedure. One patient suffered considerable pain for 2 weeks. The adverse event may have contributed to death in two patients and in a third patient was life-threatening.

Bain BJ, 2004-10: Survey for the British Society for Haematology covering 2002: 53 centres reported 13,506 procedures with 17 adverse events; the adverse event may have contributed to death in two patients and was life-threatening in a third. C9-18 bone marrow biopsy, UK 2002 survey. Study type: retrospective multicentre questionnaire survey for the British Society for Haematology, 12 months of 2002; 53 centres, 13,506 procedures (3,927 aspiration biopsies, 9,579 combined procedures). Country: United Kingdom. Funding: no funding statement in the fetched PubMed record. Conflicts of interest: none declared in the fetched record. Device: aspiration and trephine biopsy needles; two trephine needles broke during the procedure; make/model not specified. Comparator: none. Retraction check: no retraction found in the PubMed record. Deaths are described as possibly contributed to by the adverse event, not directly attributable. Study type: uncontrolled series.