Findings of the UK national audit evaluating image-guided or image-assisted liver biopsy. Part II. Minor and major complications and procedure-related mortality. (2012)

Peer-Reviewed Study · Howlett DC, Drinkwater KJ, Lawrence D, Barter S, Nicholson T · November 9, 2012

Howlett DC et al., 2012-11-09: National audit of 3,486 liver biopsies in 87 UK radiology departments (2008) found four hemorrhage-related deaths, a procedure-related death rate of 0.11%, against an audit standard of <0.1%. Fifteen further patients had at least one major complication.

There were four hemorrhage-related deaths, and this target was narrowly missed (rate achieved in practice, 0.11% [four of 3486 patients]).

Howlett DC et al., 2012-11-09: National audit of 3,486 liver biopsies in 87 UK radiology departments (2008) found four hemorrhage-related deaths, a procedure-related death rate of 0.11%, against an audit standard of <0.1%. Fifteen further patients had at least one major complication. C9-1 liver biopsy, UK national audit. Study type: prospective national audit (Royal College of Radiologists), first 50 consecutive liver biopsies per department in 2008; 3,486 patients from 87 of 210 invited departments (41%). Country: United Kingdom (England, Wales, Scotland, N. Ireland departments invited). Funding: no funding statement in the fetched PubMed record. Conflicts of interest: none declared in the fetched record. Device: image-guided or image-assisted liver biopsy; needle make/model not specified in the abstract (Part I of the audit, Radiology 2012, covers procedural technique). Comparator: none (audit against pre-set standards: death <0.1%). Retraction check: no retraction or expression of concern found in the PubMed record. Published Radiology 2013;266(1):226-235; epub 9 Nov 2012. Summary figure is procedure-related death only, not all-cause mortality. Study type: uncontrolled series.