Incidence of bleeding after 15,181 percutaneous biopsies and the role of aspirin (2010)

Peer-Reviewed Study · Atwell TD, Smith RL, Hesley GK, Callstrom MR, Schleck CD, Harmsen WS, Charboneau JW, Welch TJ. · March 2010

Atwell TD et al., 2010-03: Retrospective single-centre review of 15,181 imaging-guided percutaneous core biopsies (2002-2008). Seventy haemorrhages (0.5%) of CTCAE grade 3 or greater occurred within three months; bleeding incidence was 0.5% after liver biopsy, 0.7% after kidney biopsy, 0.2% after lung biopsy, 1.0% after pancreas biopsy and 0.2% for other organs.

The incidence of bleeding after liver biopsy was 0.5%; kidney biopsy, 0.7%; lung biopsy, 0.2%; pancreas biopsy, 1.0%; and other biopsy, 0.2%.

Atwell TD et al., 2010-03: Retrospective single-centre review of 15,181 imaging-guided percutaneous core biopsies (2002-2008). Seventy haemorrhages (0.5%) of CTCAE grade 3 or greater occurred within three months; bleeding incidence was 0.5% after liver biopsy, 0.7% after kidney biopsy, 0.2% after lung biopsy, 1.0% after pancreas biopsy and 0.2% for other organs. C7 row X1 (organ-specific bleeding rates in one institution). Study type: retrospective single-centre cohort. Subjects: 15,181 biopsies. Country: United States (Mayo Clinic, Rochester MN). Funding: not stated in the retrieved abstract. Conflicts: no conflict-of-interest statement in the retrieved PubMed abstract. Device: percutaneous core biopsy needles of varying size (needle size recorded; association with bleeding not significant, p = 0.97). Comparator: aspirin within 10 days vs no aspirin; organ subgroups. Retraction check: no retraction notice in the PubMed record.