Royal College of Pathologists (RCPath), 2021-08: UK Royal College of Pathologists tissue pathway for breast screening biopsy and cytology, which sets out the core-biopsy technique and the B1-B5 reporting categories used in the UK programme.
Breast core biopsy should be performed with a spring-loaded device, usually 14G diameter.
Royal College of Pathologists (RCPath), 2021-08: UK Royal College of Pathologists tissue pathway for breast screening biopsy and cytology, which sets out the core-biopsy technique and the B1-B5 reporting categories used in the UK programme. Fills F1 (serves C2) – national technical standard, not a study; United Kingdom, G150 4th edition, August 2021. Technique exactly as printed: spring-loaded device, usually 14G diameter; local anaesthetic to skin and down to the lesion; a small 2 mm skin nick; an assistant to compress the breast between needle passes. Sampling volume as printed: larger gauge vacuum probes can retrieve 400 mg per core, diagnostic samples of borderline lesions should aim for around 2 grams of tissue, and about 4 grams for vacuum-assisted excision of a B3 lesion. Marker placement as printed: for all VAB procedures, and where small clusters of calcification may have been completely removed. Reporting categories B1-B5 are set out in section 3.5. The document itself notes that conventional 14G core biopsy carries a high risk of an equivocal result for low-suspicion microcalcification, where larger-volume sampling may be more accurate. Funder: Royal College of Pathologists (no industry funding stated). Declared conflicts: none printed in the text captured. Comparator: none (standard-setting document). Retraction check: not a journal article; no notice applies. Read from the PDF text layer saved at text_file.