Pneumothorax rates in CT-guided lung biopsies: a comprehensive systematic review and meta-analysis of risk factors (later evidence bearing on the 2003 standard) (2020)

Peer-Reviewed Study · Huo YR, Chan MV, Habib AR, Lui I, Ridley L · 2020

Huo YR et al., 2020: Later meta-analysis of 36 studies (23,104 patients) whose pooled pneumothorax rate of 25.9% and chest-drain rate of 6.9% exceed the 20.5% and 3.1% figures the 2003 BTS standard set, and which reports that lateral decubitus positioning with the biopsied lung dependent lowers pneumothorax risk.

Pneumothorax risk was significantly reduced in the lateral decubitus position where the biopsied lung was dependent compared to a prone or supine position [odds ratio (OR):3.15].

Huo YR et al., 2020: Later meta-analysis of 36 studies (23,104 patients) whose pooled pneumothorax rate of 25.9% and chest-drain rate of 6.9% exceed the 20.5% and 3.1% figures the 2003 BTS standard set, and which reports that lateral decubitus positioning with the biopsied lung dependent lowers pneumothorax risk. Fills F1 (serves C4) – the later study that challenges the 2003 BTS technique standard, recorded alongside it; systematic review and meta-analysis of 36 articles, 23,104 patients, nine databases to September 2019; Australia; no funder or conflict statement in the PubMed record. Where it differs from Manhire et al.: pooled pneumothorax 25.9% versus the 20.5% the 2003 standard asks operators to match, and chest drain 6.9% versus 3.1%; and it reports that position changes risk – lateral decubitus with the biopsied lung dependent lowers it (OR 3.15 for the comparison against prone or supine), puncture site up through a CT-table window raises it (OR 4.79), needles 18 G or larger raise it versus smaller (OR 1.55) – whereas the 2003 standard advises prone or supine positioning and states there is no correlation between needle size and pneumothorax. Both documents are recorded; the discrepancy is not resolved by either. Retraction check: CommentIn in Br J Radiol 2021, no retraction. Also filed as BXB-031 (claims C4, F1). Study type: review.