Piccinino F et al., 1986: Multicentre retrospective survey of 68,276 percutaneous liver biopsies performed from 1973 to 1983. Death occurred in 9/100,000 biopsies, always from haemoperitoneum and only in patients with malignancy or cirrhosis; serious haemorrhagic complications were more frequent with the Trucut needle than the Menghini needle (3/1000 vs 1/1000).
Death, serious haemorrhagic complications, pneumothorax and biliary peritonitis were more frequent after biopsy with the Trucut needle than after biopsy with Menghini's needle (3/1000 against 1/1000).
Piccinino F et al., 1986: Multicentre retrospective survey of 68,276 percutaneous liver biopsies performed from 1973 to 1983. Death occurred in 9/100,000 biopsies, always from haemoperitoneum and only in patients with malignancy or cirrhosis; serious haemorrhagic complications were more frequent with the Trucut needle than the Menghini needle (3/1000 vs 1/1000). C7 row L6. Study type: multicentre retrospective survey. Subjects: 68,276 biopsies, 1973-1983. Country: Italy. Funding: not stated in the retrieved abstract. Conflicts: no funding or conflict-of-interest statement appears in the retrieved PubMed abstract (pre-ICMJE format). Device: Trucut vs Menghini needle. Comparator: needle type and underlying liver disease. Retraction check: no retraction notice in the PubMed record. Also filed as BXB-020 (claims C3, C7).