Intensity-modulated radiotherapy versus stereotactic body radiotherapy for prostate cancer (PACE-B): 2-year toxicity results from an open-label, randomised, phase 3, non-inferiority trial (2022)

Peer-Reviewed Study · Tree AC, Ostler P, van der Voet H, Chu W, Loblaw A, Ford D, Tolan S, Jain S, Martin A, Staffurth J, Armstrong J, Camilleri P, Kancherla K, Frew J, Chan A, Dayes IS, Duffton A, Brand DH, Henderson D, Morrison K, Brown S, Pugh J, Burnett S, Mahmud M, Hinder V, Naismith O, Hall E, van As N, PACE Trial Investigators · September 13, 2022

Tree AC et al., 2022-09-13: PACE-B randomized 874 men to control radiotherapy (78 Gy/39 fractions or 62 Gy/20 fractions) or SBRT (36.25 Gy/5 fractions); at 24 months RTOG grade 2+ genitourinary toxicity was 2% vs 3% and grade 2+ gastrointestinal toxicity 3% vs 2%, with no grade 4 or worse events and no treatment-related deaths.

RTOG grade 2 or worse gastrointestinal toxicity was seen in 11 (3%) of 382 participants in the CRT group versus six (2%) of 384 participants in the SBRT group (absolute difference -1·3% [95% CI -3·9 to 1·1]; p=0·32).

Tree AC et al., 2022-09-13: PACE-B randomized 874 men to control radiotherapy (78 Gy/39 fractions or 62 Gy/20 fractions) or SBRT (36.25 Gy/5 fractions); at 24 months RTOG grade 2+ genitourinary toxicity was 2% vs 3% and grade 2+ gastrointestinal toxicity 3% vs 2%, with no grade 4 or worse events and no treatment-related deaths. PMID 36113498. Design: open-label, multicentre, randomised phase 3 non-inferiority trial (PACE-B cohort). N=874 randomized (441 CRT, 433 SBRT); 844 analysed for late toxicity. Country: UK, Ireland, Canada (35 hospitals). Population: low- or intermediate-risk localized adenocarcinoma, Gleason 4+3 excluded, WHO PS 0-2; ADT not permitted. Arms: CRT 78 Gy/39 fractions over 7.8 weeks or 62 Gy/20 fractions over 4 weeks (protocol amendment 24 Mar 2016) vs SBRT 36.25 Gy/5 fractions over 1-2 weeks. Co-primary toxicity endpoints: RTOG grade 2+ GI and GU at 24 months. Funder: Accuray and Cancer Research UK (grants 28990, 28284, C7224/A28724, C33589/A28284, C1491/A15955). COI: ACT reports Accuray funding for PACE trials, personal fees from Elekta, Janssen, Accuray; other authors' declarations in article. Maker: Accuray (CyberKnife) funded the trial and makes one of the SBRT delivery platforms. Retraction check: PublicationType = Journal Article, Randomized Controlled Trial, Research Support Non-US Gov't, Equivalence Trial; PubMed comments field lists two Lancet Oncol correspondence items (2022;23(12):e530 and 2023;24(5):e192), not retractions. Registered NCT01584258. text_file=C2-05.txt [copyright as stated: Copyrighted; abstract text quoted from the PubMed record] Study type: randomized trial.