U.S. Food et al., 2012-06-14: FDA's Summary of Safety and Effectiveness Data for the p2PSA/phi PMA. It states the indication (aid in distinguishing prostate cancer from benign prostatic conditions in men aged 50 years and older with total PSA >4.0 to <10.0 ng/mL and non-suspicious DRE) and describes the single multi-centre pivotal trial: 658 men enrolled at 7 U.S. clinical sites, samples tested at three U.S. laboratories, enrollment April 2008-June 2009, 97% prospective.
Beckman Coulter subject enrollment occurred from April 2008 through June 2009 for subjects who received their medical care (blood draw, DRE, biopsy) from April 2004 through June 2009. Enrollment was by 7 clinical sites in the United States and testing of the clinical samples were performed at three clinical laboratories in the United States.
21
U.S. Food et al., 2012-06-14: FDA's Summary of Safety and Effectiveness Data for the p2PSA/phi PMA. It states the indication (aid in distinguishing prostate cancer from benign prostatic conditions in men aged 50 years and older with total PSA >4.0 to <10.0 ng/mL and non-suspicious DRE) and describes the single multi-centre pivotal trial: 658 men enrolled at 7 U.S. clinical sites, samples tested at three U.S. laboratories, enrollment April 2008-June 2009, 97% prospective. C7 SSED P090026. Document type: FDA premarket-approval scientific review (SSED), not a journal article. Pivotal study as described in the SSED: multicentre, prospective (97% prospectively, 3% retrospectively enrolled), 658 men (324 with prostate cancer, 334 without), 7 U.S. clinical sites, three U.S. clinical laboratories, enrolment April 2008-June 2009 for care delivered April 2004-June 2009, median age 63, 81.4% Caucasian, 99.1% with >=8 cores. Population: men >50 years, non-suspicious DRE, total PSA >4 to <10 ng/mL, no prior prostate cancer. Comparison: %free PSA (primary null hypothesis: phi specificity at 95% sensitivity no greater than %fPSA). Device maker and study sponsor: Beckman Coulter, Inc. (the applicant). Funding: the trial was sponsored by the PMA applicant; the SSED carries no separate grant or funding statement and no author conflict-of-interest disclosures (it is an FDA document). Safety: 'There was no adverse effect due to the device in the PMA clinical study given that the device results were not used to make biopsy recommendations.' No retraction/erratum applies. The K112603 510(k) of 2011-11-04 covers 'ACCESS HYBRITECH P2PSA QC ON THE ACCESS IMMUNOASSAY SYSTEMS', product code JJX (single specified analyte controls), i.e. the control kit, and is a separate clearance from this assay approval. Study type: regulatory record.