Wasiak J et al., 2013-03-28: Cochrane review of 30 randomised trials of dressings for superficial and partial-thickness burns; silver sulphadiazine healed more slowly than biosynthetic, silver-containing and silicon-coated dressings, and the overall evidence was of poor quality.
In the context of this poor quality evidence, silver sulphadiazine (SSD) was consistently associated with poorer healing outcomes than biosynthetic (skin substitute) dressings, silver-containing dressings and silicon-coated dressings.
Abstract, MAIN RESULTS
Wasiak J et al., 2013-03-28: Cochrane review of 30 randomised trials of dressings for superficial and partial-thickness burns; silver sulphadiazine healed more slowly than biosynthetic, silver-containing and silicon-coated dressings, and the overall evidence was of poor quality. C4. Study type: systematic review of 30 RCTs, international (Australia-led, Cochrane Wounds Group); silver forms covered: silver sulphadiazine cream and silver-containing dressings, not colloidal silver gel; comparator: biosynthetic, silicon-coated, hydrogel and other dressings; declared conflicts: 'None' in the record's conflict statement; no retraction notice found. Mixed for silver: silver-containing dressings were associated with better healing than silver sulphadiazine, while silver sulphadiazine healed worse than non-silver biosynthetic and silicon-coated dressings; the authors rate the evidence poor quality. Study type: review.