Relations between erythemal UV dose, global solar radiation, total ozone column and aerosol optical depth at Uccle, Belgium (2014)

Peer-Reviewed Study · V. De Bock, H. De Backer, R. Van Malderen, A. Mangold, A. Delcloo (Royal Meteorological Institute of Belgium) · November 20, 2014

V. De Bock et al., 2014-11-20: A 1991-2013 analysis of erythemal UV dose at Uccle, Belgium, showing that global solar radiation, total ozone and aerosol optical depth together explain 94% of the variation in UV dose, with global radiation alone explaining 56%; a multiple-regression model reproduces the measurements with a summer mean error of 6%.

The summer model gives the best performance, with an absolute mean error of only 6 %.

PDF page 21

V. De Bock et al., 2014-11-20: A 1991-2013 analysis of erythemal UV dose at Uccle, Belgium, showing that global solar radiation, total ozone and aerosol optical depth together explain 94% of the variation in UV dose, with global radiation alone explaining 56%; a multiple-regression model reproduces the measurements with a summer mean error of 6%. C9 De Bock et al. 2014. Document type: measurement and regression study (simultaneous erythemal UV, global solar radiation, total ozone column and aerosol optical depth, 1991-2013, Uccle). Country: Belgium. Funder: Royal Meteorological Institute of Belgium (institutional). Conflicts: none declared. Quote is from the abstract; the subscripted symbols render as Sery/Sg/QO3 in the extracted text, and the quote is copied in that form. Open access under CC BY 3.0. Study type: other.