National Atmospheric Deposition Program, 2026-01-21: Step-level field SOP for the weekly bucket change: approach from the downwind side, clean laboratory gloves, keep the lid and bucket lip untouched, note contamination sources; it is the concrete 'clean-hands, clean-bottle' procedure behind NADP precipitation sampling.
Use care when handling the sample bucket and lid to avoid contaminating the sample. NTN samples are analyzed for sodium, chloride, and potassium all of which are present in sweat.
p. 1
National Atmospheric Deposition Program, 2026-01-21: Step-level field SOP for the weekly bucket change: approach from the downwind side, clean laboratory gloves, keep the lid and bucket lip untouched, note contamination sources; it is the concrete 'clean-hands, clean-bottle' procedure behind NADP precipitation sampling. text_file=nadp_ntn_changeout.txt Revision date 01/21/2026. Precautions section. The procedure also requires clean lab gloves in the supplies list and cleaning of the collector each change-out. Study type: regulatory record.